Another Luminol Experiment

for anything else that doesn't fit.
Post Reply
User avatar
Robb
Posts: 2062
Joined: 01 Jun 2006, 10:00
State/Location: NSW

Another Luminol Experiment

Post by Robb »

The following Luminol method is my favourite and works well with the chemicals I worked with.

Luminol Solution:

Dissolve 4g of Sodium Carbonate in 500mL of Distilled Water (This brings the pH to approx 11 which I found to be optimum for dissolving Luminol).

Add 0.2g of Luminol and dissolve.

Add 25g of Ammonium Carbonate and 0.2g of Ammonium Carbonate (This re-Buffers to pH of around 10.5, I found this to be optimum for this reaction).

Dilute to 1L with distilled Water. (Use only 25 mL at a time as this makes the solution last for a few experiments).

Oxidising Solution:

~ With K[sub]3[/sub]FeCN[sub]6[/sub] (Potassium Ferricyanide)

0.76g of K[sub]3[/sub]FeCN[sub]6[/sub]

Dissolve in 25mL of 5% H[sub]2[/sub]O[sub]2[/sub].

Mix these solutions together to begin the reaction

This reaction here will produce a lasting glow for more than 50 seconds.

I hope this adds to everyone's repertoire of Luminol Experimentation.

Robb……
Last edited by Robb on 29 Aug 2006, 13:50, edited 1 time in total.
Dr Robert Crosdale. MRACI. NSS. NSSA. NASA.
Ph.D (Chem), Post Grad Ph.D (Physics), M.Ed, B.Sc (Hons), Dip. Appl. Sc. (Chem)
Lake Munmorah High School.
University of New England.
University of New South Wales.
University of Newcastle.

To understand the Universe from our perspective, we need to look towards our own backyard first for answers.

** AD ASTRA PER ASPERA - SEMPER EXPLORO **
User avatar
juliem
Posts: 61
Joined: 15 Jun 2006, 10:00
State/Location: NSW

Post by juliem »

For all those
doing the Forensics Prac
ARE YOU USING BLOOD -please ref CSIS
therefore is Luminol necessary
an alternative is red jelly and ph adjust then use an indicator
juliem
Last edited by juliem on 29 Aug 2006, 18:12, edited 1 time in total.
User avatar
Robb
Posts: 2062
Joined: 01 Jun 2006, 10:00
State/Location: NSW

Just to Re-iterate

Post by Robb »

Just to re-iterate what juliem has mentioned,

These pracs rely on the Oxidising solution in combination with the Luminol to produce the Chemiluminescence reaction.


All of which are indicated in each Method I have outlined and there is no need for any blood product. These reactions are purely Chemical!

Hope this avoids any confusion..

Robb.......
Dr Robert Crosdale. MRACI. NSS. NSSA. NASA.
Ph.D (Chem), Post Grad Ph.D (Physics), M.Ed, B.Sc (Hons), Dip. Appl. Sc. (Chem)
Lake Munmorah High School.
University of New England.
University of New South Wales.
University of Newcastle.

To understand the Universe from our perspective, we need to look towards our own backyard first for answers.

** AD ASTRA PER ASPERA - SEMPER EXPLORO **
User avatar
Steph
Posts: 30
Joined: 25 May 2006, 10:00
State/Location: NSW

Post by Steph »

Don't worry, Julie, the blood we use is saved from dissections (luckily they are doing them at the same time). No human products !
Post Reply